ST302G Ionizer Gun

ST302G Ionizer Gun

Action Principle
It is a static electricity eliminating device with static electricity and dust. Under the action of high voltage
and low current, it produces a large number of ion airflow groups with positive and negative charges, which
reach the surface of the object by the powerful airflow generated by the air compressor and effectively
neutralize the charges on the surface of the object, thus achieving the purpose of eliminating static electricity;
The action distance of ions can reach 1 meter, which is especially suitable for occasions and environments
where human hands cannot approach.
Product Features:
1. Safety-oriented construction (except electrostatic capacity combination)
2. The wind nozzle can be used singly or in combination, and can remove electricity and dust in a wide range
3. Quick elimination of static electricity makes it easier to clean small sensitive parts and materials
4. Ion wind nozzle has good grounding protection function
5. It is especially suitable for occasions and environments that cannot be accessed by human hands, and can be set
for automatic control
6. Easy to move and install
7. Stickon ST402A high-voltage generator is required for integrated use
Product Use:
1: Used to remove static electricity from resin film.
2: De-electricity and dust removal for products with complex shapes.
3: Cleaning the interior of resin container.
4: Localized electricity removal in small areas.
5: Electrostatic elimination of other resin pressed products.
Technical Parameter
Model | ST302G |
Color (solid part) | Blue |
Special method of minimum pitch (mm) connection type | 80 |
Weight (each, about g) | 550 |
Operating ambient temperature (℃) | 0 ~ 40 (no frost) |
Electrode structure | Capacity combination type |
High voltage cable length (m) | 3 |
Enter air pressure (MPa) | 0~0.7 |
Ion consumption (about Nl/min) (when air pressure is 0.5MPa) | 171 |
Screw size of air joint (simple operation joint) | PT1/8 |
Outside diameter of applicable trachea (mm) | 6 |
Use high voltage (kVac) | 7 |
Charged decay time (seconds) | Power supply device 7, power supply device 150 (defining the type of shielded cable) |
Ion balance loop (compensation voltage) | None |
Suitable power supply device | Power supply device 7, power supply device 150 (defining the type of shielded cable) |
※Ion wind nozzle is a non-explosion-proof commodity.
※Charged decay time: 20pF charged plate is needed when 500V is gradually reduced, the distance between
charged plate and each electrode is 100mm when the charged plate voltage is 5KV, and MPa is the ion
pressure during measurement.
※Ion balance: Use an anode display with a distance of 100mm and an ion pressure of 0.2MPa
※Each data is a measured value, not a guaranteed value.
Product Size