Installation and use method of ionic air nozzle
Attention should be paid when using ionic air nozzles:
First, the requirements of power supply and air source
1, the power supply must have ground, and to ensure full grounding, transformer must ensure good grounding, before each use to check whether the grounding wire knob is tightened. Ionic air nozzle is a high voltage energized product, so each energized working time can not exceed 16 hours. Otherwise: high pressure leads to high voltage line, wind nozzle head heating, ion needle and ground wire ignition, resulting in plastic parts gradually formed honeycomb coke loss, ion removal is also gradually reduced, and even cause security risks.
2. All air sources must be effectively filtered. Sometimes a secondary filter is required. The screening program should be cleaned in time. Otherwise: water, oil and dust/dust particles will enter the ion generation chamber and adhere to the inner wall of the plastic parts. At a certain point, the ionic needle ignites it. Results The cellular coke loss of plastic parts was gradually formed, and the ion discharge was gradually reduced, which affected the effect of electric removal, especially caused security risks and even ignition.
Two, in addition to static effect adjustment
1, in addition to electrostatic effect in addition to electrostatic time and air pressure is inversely proportional. Pressure should be 0.2Mpa-0.5mpa.
2. The distance and Angle between the nozzle and the electrostatic field affect the electrostatic effect, so attention should be paid to debugging until satisfactory.
Three, daily maintenance
1. The head of the air nozzle is easy to break. Pay attention to prevent collision when using the air nozzle and prevent falling after use. Care should be taken to prevent objects from colliding even with fixed air nozzles.
2. Do not use the water to wipe the wind snake head and the wind mouth, so as not to corrode the plastic parts and further affect the ion balance.
2, for the production of high precision enterprises: he must ensure that there is a good, durable electrostatic removal function. The best way to clean is to use a cotton swab dipped in alcohol to clean the residue on the ion needle.
4. Keeping the air nozzle clean can not only achieve better results, but also prolong the life of the air nozzle.
Four, to inform
1. High-voltage ion air nozzle is a precise and sensitive electrostatic removal product. Under the conditions of its use, the use time can reach 10,000 ~ 15,000 hours.
2, all high voltage in addition to static equipment, in the use of work, to often check whether the product has reached the static function, there is no abnormal situation, such as the individual products are found to be different, to timely exit the working area, contact the supplier to solve.
3, the connection between the wind head and the high voltage line, do not often forcibly bend and rotate, because the connection between the wind head and the mouth rod is metal and the high voltage line is easy to break, easy to cause ignition discharge burn; Air nozzle is a high voltage electronic product, to achieve the principle of power off.
4. All products are not under the condition of ungrounded power supply and unclean air source, and the failure, damage and other consequences caused by careless use are not within the scope of our warranty and responsibility.