High-frequency DC ion nozzle with built-in subminiature piezoelectric transformer.

 

This product is designed by professionals, with less brackets, convenient installation and direction adjustment.

 

Mainly used in electronic assembly line, painting industry, medical machinery manufacturing and packaging, semiconductor

 

 production and flat panel display manufacturing, packaging, injection molding production, photoelectric and other industries.

 

 

Product Features:

 

High reliability: Adopt air connector to improve ozone resistance.

 

Ensure safety: Adopt transformer box with new structure, and stop high voltage output when cleaning and replacing discharge needle

 

Nozzles with improved ozone resistance: All kinds of nozzles with high ozone resistance

 

Easy to maintain: The discharge needle is detachable and easy to maintain, and can be pulled out together with the transformer from

 

 the rear to clean and replace the discharge needle conveniently.

 

High-voltage stop alarm: It has alarm display function during high-voltage stop and is equipped with normally open and normally

 

closed double contacts without signal contact.

 

Clean check "C.C": It is also equipped with normally open non-signal contact

                                                                            

Technical Parameter

 

Input power supply:

DC+24V±10%

Capacity:

2.4VA

Output voltage:

High frequency 3000V

Ion balance:

Under ±10V

Use air pressure:

0.05Mpa~0.6Mpa

Air flow:

30L/min~160L/min

Ozone generation:

Under 0.05ppm (input air pressure: 0.02Mpa, measuring distance: 300mm)

Working guarantee temperature:

10~40℃ (Save at -10℃~60℃)

Work guarantee humidity:

~75% or less, but no condensation (keep it below -90%, no condensation)

Main body size:

87×23×41mm(L×W×H) (including protrusion, size of individual nozzle head) with a total length of 650mm including base

Main body weight:

1.35kg

Attachments:

Enter power cable + Nozzle + Instruction manual

 

Note 1: The nozzle was measured with a 150mm, 20pF Charged plate monitor

 

Note 2: The static removal time is the attenuation time from ±1000V→±100V, and the static removal time is less than <1.5S s.

 

Note 3: The measured distance is 50mm from the flat panel monitor

 

Note 4: Test standards: ANSI/ESD.STM3.1, ANSI/ESD.SP3.3, SJ/T 11446 - 2013

 

Product Size


image.png


Optional accessories

High Frequency AC Ion Nozzle

AC small ionizer with built-in subminiature piezoelectric transformer


image.png


Action Principle

 

ST-6 high-frequency AC type ion nozzle applies the international advanced technology and adopts small piezoelectric transformer to

 

change the input direct current into high-frequency low-voltage alternating current.

 

The discharge needle made of special alloy material makes the discharge stability and wear resistance of the needle surpass the

 

commonly used metal discharge needle.

 

The discharge needle can be replaced, and ST-6 has built-in electrostatic removing electrode for corona discharge to generate ions.

 

Maintenance

 

1. Adjustment of electrostatic removal effect

 

①. Static removal effect Static removal time is inversely proportional to air pressure. The air pressure should be 0.3Mpa-0.7Mpa.

 

②. The distance and angle between the nozzle head and the electrostatic field all affect the electrostatic effect, so we should pay

 

attention to debugging until we are satisfied.

 

2. Daily Maintenance

 

①. Pay attention to anti-collision when using nozzle, and pay attention to anti-falling after use. Even if the nozzle is fixedly

 

installed, care should be taken to prevent objects from colliding.

 

②. Clean the ion needle and ion needle chamber of nozzle with absolute alcohol, but not with water from Tianna. When cleaning,

 

turn off the power first, then screw off the small plastic cover (also called air accelerator) in front of the nozzle head with a camera,

 

and clean the ion needle and the inner chamber of the ion needle with a cotton swab dipped in absolute alcohol to clean the internal

 

stains and dirt.

 

. Timely cleaning and maintenance can not only improve the use effect, but also prolong the service life.


销售部经理:黄德忠 13509222289

业务部:王丹静:13790228779

               Dany: 13713227588 

售后服务电话:0769-82582071

电 话:0769-85592234 / 82582071 传 真:0769-85960809

公司邮箱:stickon@126.com 地 址:广东省东莞市厚街镇新塘古坑运河西路1号二楼(总部)

思帝克产品生产研发中心:广东省顺德大良五沙工业区华腾高新科技城五栋思帝克大厦  帷幄网络技术支持

Copyright © 2002-2015 思帝克科技(广东)有限公司  版权所有   备案号: 粤ICP备2021028066号 

扫一扫关注微信