Daily maintenance of electrostatic eliminator
Ionic wind rod has a wide range of applications in many electronic industries. It is used for large-scale and super-large-scale integrated circuit clean workshops to avoid human body in
Movement in the workshop generates static electricity. At the same time, the ionic wind rod is sometimes necessary in the use of some wear and tear. So we have to periodically pair the ions
The wind rod is maintained and maintained, so how do we maintain and maintain the ionic wind rod well?
In industrial production, due to the friction, stripping, extrusion and induction between objects, the surface area of objects has different properties of charge. When this
When the kind charge accumulation reaches a certain degree, the industrial products will produce electrostatic adsorption and discharge phenomenon. Electrostatic charge accumulation and discharge on industry
It can cause a lot of impact and damage. The role of ionic wind rod is to use air ionization to produce a large number of positive and negative charges, and dry clean pressure
Shrinking air blows out positive and negative charges. It creates a stream of positive and negative charges that neutralize the charge on the surface of the object. When the surface of an object is
When it has a negative charge, it attracts a positive charge in the flow, when it has a positive charge on the surface, it attracts a negative charge in the current, and so on
The static electricity on the surface of the object is neutralized to eliminate static electricity. If there is dust on the surface of the electric needle, the ionic wind will be blocked
The discharge needle of the rod ionizes the air into positive and negative charge, and the load increases under long working time, thus producing certain heat, making its plastic parts performance
Falling, resulting in embrittlement phenomenon.
How to maintain:
1. In the process of using the ionic wind rod, when the tip of the needle accumulates dust or debris, it must be cleaned in time.
2, with electrostatic brush, dust-free cloth dipped in anhydrous industrial alcohol gently remove dust on the shell of the ionic wind rod, at least once a week.
Items used in daily maintenance:
Instructions for operation:
1. During the use of ionic wind rod, how to clean the dust or debris on the launching tip of ionic wind rod
2. How to clean dust on the shell of ionic wind rod -- detailed operation as shown in the figure below
▲ It must be operated 10 minutes after the power is cut off.
▲ After cleaning, you must wait for alcohol to volatilize completely, and then power on the work, can not use any other organic solvents to clean the bar body.
Matters needing attention:
1. The power input power of a power box must be connected to a reliable ground terminal.
2. The ground cable of the ionic wind rod must be connected to the ground terminal of the power box to ensure user safety.
3. The device should not be used in rain or wet environment.
4. Do not use the device in inflammable and explosive environment.
5. It is strictly forbidden to disassemble products without authorization. Internal maintenance and repair must be carried out by professional personnel.
6. Turn off the power when checking or replacing the product; otherwise, electric shock or fire may occur.
7. Specially designed for removing static electricity, it is forbidden to use for other purposes, any abnormal use may cause machine failure, electric shock, fire and other hidden dangers.
8. It is forbidden to touch the electrode needle under the state of power-on, otherwise it may cause fault and electric shock accident.
9. Electroacupuncture is a sharp metal object, please use it with care.
Before powering on the product, check the specifications of the power supply. Any power supply that does not meet the specifications may damage or even malfunction the product