A static eliminator also called ionizer or electrostatic eliminator is a device which can neutralize static charge by generatingpositive and negative ions that offset the existing imbalance of ions .
If we take ions with us , we may attract dust and airborne particles. And it may take into working space which could take damage to the products especially for electronic parts .
A.Food & Pharmaceutical Industries
Problem caused by static :
u Dust Cannot be Removed With Air Shower
u Pills Escaping During Blister Packaging
u Caps Stuck During Transfer
u Jamming During Heat Seal Packaging
u Electronic Balance Showing Unstable Values
u Cam Positioner Malfunction on Pack Transfer Conveyor
u Dust Adhesion Inside Resin Containers
u Powder Escaping During Filling Process
B. Resin & Film Industries
Problem caused by static :
u Molded Resin Parts Remaining in Mold
u Parts Stuck in Feeder Bowl
u Trapping of Resin Film During Roll Transfer
u Film Clinging to Blade After Cutting
u Misaligned Bonding of Disks
u Improperly Positioned Labels on Resin Bottles
u Cutting Swarf Adhering to Resin Parts
u Color Irregularity During Disk Label Printing
C. Electrical Equipment Industry
Problem caused by static :
u Dust Adhesion During Camera Parts Assembly
u Dust Adhesion During Mobile Phone Assembly
u Dust Adhesion During Assembly/Inspection of HDD Motors
u Damage to IC Parts During Cell Process Work
u Solder Splashing During Cream Solder Printing
u Damage to Electronic Components During Final Inspection of Electronic PCBs
u Damage to Electronic Components During Transfer of Electronic PCBs
D. Electronic Device Industry
Problem caused by static :
u Pin Holes in Lithium Ion Battery Separators
u Trapping of Protective Film During Fuel Cell Sheet Unwinding
u Components Escaping During LED Taping
u Tearing of Ceramic Green Sheet During Protective Film Removal
u Blurry Ink in Screen Printing of Electronic PCBs
u Uneven Coating on Electronic PCBs
u Electronic Components Stuck in Feeder Bowl
u ESD Damage During IC Chip Pickup
E. Glass & Rubber Industries
Problem caused by static :
u Disordered Optical Fiber Winding
u Dust Adhesion on Lenses Between Cleaning and Deposition
u Uneven Lens Coating
u Adhesion of Dust Generated by Shot Blasting
u Entangled Packaging Material During Tire Wrapping
u Adhesion of Foreign Particles and Electric Shock of Workers During Material Winding
F. Paper & Textile Industries
Problem caused by static :
u Malfunction of BM Meter in Paper Making Line
u Problems With Offset Printers
u Trapping of Paper Sheet During Roll Transfer
u Paper Misalignment in Press Stacker
u Chips Remaining on Blade of Punching Press (Slug Pulling)
u Dust Adhesion During Non-woven Fabric Cutting Process
u Paper Sticking During Collation (Page Arrangement)
u Meandering Glue Application on Cardboard Boxes
G. Metal Industry
Problem caused by static :
u Dust Adhesion on Copper Foil Surface
u Cutting Swarf Adhering to Aluminum Sashes
u Misalignment of Steel Plate and Film
u Trapping of Cold-rolled Coil Protective Sheet
H. Automotive Industry
Problem caused by static :
u Defective Bumper Coating Due to Dust Adhesion
u Resin Parts Remaining in Mold
u Cutting Swarf Adhering to Tools
u Damage to Electronic Components on PCBs When Touched by Workers
u Defective Electrostatic Coating Due to Dust Adhesion
u Contamination Inside Headlamps
u Dust Adhering to Resin Panels
Voltage application systems utilizing corona discharge are constructed from: needle shaped electrodes that apply a high voltage; a high voltage power source; and grounding electrodes. Applying high-voltage to the electrodes produces a corona discharge on the needle tips.
When a corona discharge occurs and the air surrounding the electrode needles is broken down, ions are produced.
Using these ions, reverse-polarity static electricity is neutralized, and static is eliminated.
It's easy, hand-held, battery-operated instrument that indicates the surface voltage and polarity when held 1 inch away from the object. Another easy and quick method to check for proper operation of a Static Eliminator is to sniff for the presence of ozone near the device's emitter point(s)
Sales Manager: Huang Dezhong 13509222289
Business Department: Wang Danjing: 13790228779 13713227588
After-sales service telephone: 0769-82582071
Telephone: 0769-89791117/82582071 Transmission: 0769-85960809
Address: 2nd Floor, No. 1, Xintang Gukeng Yunhe West Road, Houjie Town, Dongguan City,
Guangdong Province (Headquarters)
Sidike Product R&d Center: Network technical support, Building 5 sidike Building, Huateng
High-tech City, Daliang Wusha Industrial Zone, Shunde, Guangdong Province
Copyright © 2002-2015 思帝克科技(广东)有限公司 版权所有 备案号: 粤ICP备2021028066号
Scan for WeChat