Can be directly placed in a variety of working areas, and set to automatic control, ion action distance up to 1 meters
Q: Can be directly placed in a variety of working areas, and set to automatic control, ion action distance up to 1 meters of the daily maintenance of the ionic wind snake
Answer: the requirement of power supply and air source
1, the power supply must have ground, and to ensure full grounding, transformer must ensure good grounding, before each use to check
Check that the ground wire knob is tightened. Ionic air nozzle is a high voltage energized product, so each energized working time can not exceed the maximum
16 hours. Otherwise: high pressure leads to high voltage wire, air nozzle head heating, ion needle and grounding wire ignition, resulting in plastic
The cellular coke loss is gradually formed in the glue parts, and the removal of ions is gradually reduced, even causing security risks.
2. All air sources must be effectively filtered. Sometimes a secondary filter is required. The screening program should be cleaned in time.
Otherwise: water, oil and dust/dust particles will enter the ion generation chamber and adhere to the inner wall of the plastic parts. Accumulated to a
To a certain degree, the ion needle will ignite it. Results Cellular coke loss was gradually formed in plastic parts, resulting in ion excretion
Also gradually reduce, affect the effect of removing electricity, especially the safety risks, and even ignition.
Two, in addition to static effect adjustment
1, in addition to electrostatic effect in addition to electrostatic time and air pressure is inversely proportional. Pressure should be 0.2Mpa-0.5mpa.
2. The distance and Angle between the nozzle and the electrostatic field affect the electrostatic effect, so attention should be paid to debugging until satisfactory.
Three, daily maintenance
1. The head of the air nozzle is easy to break. Pay attention to prevent collision when using the air nozzle and prevent falling after use. Even if the fixed installation of the air nozzle, also
Take care to prevent object collisions.
2, to regularly check the high voltage wire jacket is not damaged, if there is damage should be immediately cut off the power supply, to avoid burning off, cause severe
Heavy consequences.
3, do not use the water to wipe the wind snake head, and the wind mouth, so as to avoid corrosion of plastic parts, and further affect the ion balance.
4. Dip in anhydrous industrial alcohol with a dust-free cloth to gently remove dust on the shell of the ionic air nozzle, at least once a week
5. Keeping the air nozzle clean can not only achieve better results, but also prolong the life of the air nozzle.
Instructions for operation:
1, the power supply joint should be checked once a month, to prevent the joint in the use of high voltage water vapor is easy to cause oxidation,
It needs to be cleaned regularly with industrial alcohol.
2. During the use of ionic air nozzle, how to clean the tip of ion air nozzle when there is dust or debris
Four, to inform
1. High-voltage ion air nozzle is a precise and sensitive electrostatic removal product. Under the conditions of its use, the amount of use time can be achieved
10,000 to 15,000 hours.
2, all high voltage in addition to static equipment, in the use of work, to often check whether the product has reached the static function, there
There is no abnormal situation. If certain products are found to be abnormal, exit the working area in time and contact the supplier to solve the problem.
3. At the connection between the air head and the high voltage wire, do not bend and rotate frequently, because the connection between the air head and the mouth rod is metal and
High voltage line is easy to break, easy to cause ignition discharge burn; Air nozzle is a high voltage electronic product, to achieve the principle of power off.
4, all products in ungrounded power supply, unclean air source conditions under the use, and do not cherish the use of failure, damage
And other consequences are not within the scope of our warranty and liability.