Ac type applied voltage type electrostatic removal device, generally used for film, thin plate, paper type electrostatic removal nozzle
Product Description:
Air ion electrode can remove static electricity and dust. Please choose to use it according to the purpose and use.
The flat nozzle type air ion dust removal is more effective.
Nozzle type, flat type, adopts flat nozzle, and has strong dust removal effect with laminar air.
Product Features:
1. AC-type applied voltage electrostatic discharge device is generally used for electrostatic discharge electrodes
of film, sheet and paper
2. The structure design with low electric shock inductance is adopted, and the standard high-voltage cable length
is 1 m
3. The best setting distance of rod electrode is 30~50mm from charged object
4. The maximum response speed to electrostatic objects is 120m/ min. (If it exceeds 120m/ min, more than one
can be set to deal with it. Please consult the business department for relevant specifications.)
5. Stickon ST401A high-voltage generator is required for integrated use
High voltage generator is required: ST401A one tow two/one tow four | |
Model Parameters | ST401A |
Operating power supply | 110V/60Hz or 220V/50Hz |
Consumption current | 0.23A or 0.12A |
Power | 75W |
Operating temperature range | 0-50℃ |
Weight | 2.25kg |
Length of high voltage wire | 1.5m |
Output voltage | 4.6KV X 2 or 4 |
Output current | 4.5mA |
Can it be used in explosion-proof environment | No |
Technical Parameter
Model | ST202F |
Ion generation mode | Piezoelectric type |
Material of discharge needle | Tungsten steel |
Host material | ABS fireproof engineering plastics |
Air ion supply range | 10cm~18cm |
Air inlet pipe | Duct with inner diameterΦ6 |
Body size | 136mm (L)×42mm (W)×50mm (H) standard cable length 1M |
Accessories | Instructions/warranty cards/certificates |
Performance | Static removal time < 1.5S |
Air consumption | 0.09m³/min |
Noise | 56DB |
Ozone production | < 0.02ppm or less (measuring distance 200mm) |
Product Size
Ionic air nozzles are widely used in many electronic industries for large-scale and ultra-large scale integration
Circuit clean workshop, avoid the human body in the workshop to move static electricity. At the same time the ionic air nozzle has been used
Sometimes the journey is necessary and there is some wear and tear. So we should regularly carry out maintenance and maintenance of the ionic wind snake mouth,
So how do we maintain and maintain the ion wind snake mouth?
In industrial production, the surface of objects is accumulated because of the friction, stripping, extrusion and induction between objects
Charges with different properties. When this charge is accumulated to a certain extent, the industrial product will produce static
Electric adsorption and discharge phenomenon. Static charge accumulation and discharge will cause great influence and damage to industrial production.
The role of ionic air nozzle is to use air ionization to produce a large number of positive and negative charges, and dry clean compressed air
Blow out the positive and negative charges. It creates a stream of positive and negative charges that neutralize the charge on the surface of the object. when
When the surface of an object has a negative charge, it attracts a positive charge in the flow, when the surface of an object has a positive charge
, it will attract the negative charge in the current, so that the static electricity on the surface of the object is neutralized, to eliminate static electricity
The purpose of. If there is dust on the surface of the electric needle, it will hinder the ionization of the electric needle
The air becomes positive and negative charge, and the load increases under long working time, thus producing certain heat and making the plastic parts
Can decrease, resulting in embrittlement phenomenon.
How to maintain:
1. In the process of using the ionic air nozzle, when the tip of the needle accumulates dust or debris, it must be cleaned in time.
2, with electrostatic brush, dust-free cloth dipped in anhydrous industrial alcohol gently remove the dust on the shell of the ionic air nozzle
At least once a week.
Instructions for operation:
1. In the use of ionic air nozzle, how to clear the dust or debris at the launching tip of ionic air nozzle
2. How to clean dust on the shell of ionic air nozzle and the interface of PC spring -- detailed operation as shown in the figure below
▲ It must be operated 10 minutes after the power is cut off.
▲ After cleaning, you must wait for alcohol to volatilize completely, and then power on the work, can not use any other organic solvents to clean the bar body.
Matters needing attention:
1. The power input power of a power box must be connected to a reliable ground terminal.
2. The ground cable of the ion air snake mouth must be connected to the ground terminal of the power box to ensure user safety.
3. The device should not be used in rain or wet environment.
4. Do not use the device in inflammable and explosive environment.
5. It is strictly forbidden to disassemble products without authorization. Internal maintenance and repair must be carried out by professional personnel.
6. Turn off the power when checking or replacing the product; otherwise, electric shock or fire may occur.
7. Specially designed for removing static electricity, no other use, any abnormal use may cause machine failure, electric shock,
8. Fire and other hidden dangers.
9. It is forbidden to touch the electrode needle when the power is on, otherwise it may cause fault and electric shock accident.
10. Electroacupuncture is a sharp metal object, please use it with care.
11. Before powering on the product, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage to the product
Even breakdown.